Audio settings

Set the ASIO4ALL Sample Rate to 44.1 or 48 kHz

A sample rate is the number of samples captured or played each second. Your DAW and the selected audio endpoints need a working rate before a session can start. Use the project's delivery requirement and the device's supported rates to choose a setting.

Studio audio interface and digital recorder beside laptop with blurred detailed audio waveform
In this guide

Which ASIO4ALL sample rate should you choose?

For most sessions, set the ASIO4ALL sample rate to 44.1 kHz for music projects and 48 kHz for video, podcast and broadcast work, unless the person or service receiving your files asks for something else. Set the rate in your DAW, confirm that the selected Windows device supports it, and only reach for the resampling option if one rate fails while the other works.

A sample rate is the number of audio samples captured or played each second. ASIO4ALL v2 runs on top of the existing WDM drivers in Windows, so the rate your DAW requests has to be one the underlying device can actually run, or one the driver can convert to. This guide walks through how to pick a rate, where to set it and how to test it before a real session.

The short version

  • Match the rate of an existing project before changing anything.
  • For a new project, use the rate the delivery spec asks for.
  • Check the device documentation for supported rates.
  • Test playback and recording in an empty project at the chosen rate.
  • Keep the Always Resample option for the specific 44.1/48 kHz problem it was designed for.

44.1 kHz vs 48 kHz in practice

Both rates capture the full audible range, so the choice is mostly about where the audio is going. 44.1 kHz is common in music production, while 48 kHz is common in video workflows. Picking the rate that matches the destination avoids a conversion step later.

Higher rates such as 88.2 or 96 kHz exist and some interfaces support them, but they increase the amount of data the computer processes per second. On a built-in audio chip or a simple USB device running through ASIO4ALL, that extra load rarely pays off. Use them only when a project specifically requires them and your hardware lists them as supported.

Typical uses for common sample rates
Sample rateCommon useNotes for ASIO4ALL users
44.1 kHzMusic production and music releasesSome devices handle it internally with conversion; see the resampling section below
48 kHzVideo, podcasts, streaming and broadcastA frequent native rate on built-in audio and USB devices
88.2 / 96 kHzProjects that specifically request themOnly if the device lists support; more CPU work per second

Tip: If you are not sure what the final destination expects, ask before you record. Changing the rate of a finished multitrack session is far more work than choosing correctly at the start.

Set the ASIO4ALL sample rate in your DAW

In most hosts the sample rate is a project or audio-engine setting, not a setting inside the ASIO4ALL control panel. The DAW asks the ASIO driver for a rate when it starts the audio engine, and ASIO4ALL then opens the selected WDM devices at that rate or converts where it can.

Where to find the setting

The exact location varies by host. These are the usual places to start; check your DAW's own documentation if the layout differs in your version.

  • FL Studio: Options › Audio settings
  • Ableton Live: Options › Settings › Audio (older versions: Preferences)
  • Cubase: Studio › Studio Setup › Audio System, with the project rate in the project setup
  • REAPER: Options › Preferences › Audio › Device

Step by step

  1. Open the DAW's audio settings and select ASIO4ALL v2 as the driver.
  2. Open the ASIO4ALL control panel and confirm the input and output devices you intend to use are enabled.
  3. Set the sample rate in the DAW to 44.1 kHz or 48 kHz to match your project.
  4. Apply the change and check what the DAW actually reports as the running rate.
  5. Play a short clip, then record a few seconds on the intended input and play it back.

What the Windows default format does

The default format in the Windows Sound settings controls the Windows shared-mode audio mix, the path ordinary apps like browsers use. It can help when checking an endpoint in Windows, but the ASIO host can request its own rate for the session. Setting Windows to 48 kHz does not force your DAW to 48 kHz, and the reverse is also true.

How ASIO4ALL handles 44.1 and 48 kHz resampling

The ASIO4ALL manual describes automatic conversion when the host opens ASIO4ALL at 44.1 kHz and the underlying WDM driver does not support that rate. In that case the driver can still give your DAW a 44.1 kHz session while the hardware runs at 48 kHz.

The advanced Always Resample option covers a different case. Some hardware advertises 44.1 kHz support but handles the conversion internally with poor quality or unstable results. Turning the option on lets ASIO4ALL do the conversion instead of the device. The publisher explains the behaviour on its 44.1 and 48 kHz resampling page.

When the option is worth trying

  • 48 kHz works cleanly, but 44.1 kHz on the same device sounds rough, distorted or unstable.
  • The problem follows the 44.1 kHz rate rather than the buffer size or a particular plug-in.
  • You have already confirmed the same device and settings in an empty project.

Watch out: Always Resample is not a general fix for crackles. If the noise is present at both 44.1 and 48 kHz, the cause is more likely the buffer, a busy system or the device itself. Work through the crackling and dropout guide instead.

Testing it properly

If 48 kHz works and 44.1 kHz fails, test both rates in an empty project with the same device selected. Check the relevant device in the ASIO4ALL control panel before changing its setting. A known-good 48 kHz project gives you a clean comparison: if the 44.1 kHz session improves with the option on and the 48 kHz session stays the same, you have found the right fix.

How sample rate changes buffer timing

The ASIO buffer is measured in samples, but what you feel when playing a virtual instrument is time. The conversion is simple: samples divided by sample rate, multiplied by 1000, gives milliseconds. Because 48 kHz plays more samples per second, the same buffer is slightly shorter in time than at 44.1 kHz.

Duration of one ASIO buffer at 44.1 and 48 kHz
Buffer sizeAt 44.1 kHzAt 48 kHz
64 samplesabout 1.45 msabout 1.33 ms
128 samplesabout 2.90 msabout 2.67 ms
256 samplesabout 5.80 msabout 5.33 ms
512 samplesabout 11.61 msabout 10.67 ms
1024 samplesabout 23.22 msabout 21.33 ms

Those figures describe one block. The complete recording and monitoring path can add hardware, driver and application delay on top. For help choosing a value, see the ASIO4ALL buffer size guide or the publisher's buffer size page.

Do not double the rate to cut latency

Running at 96 kHz does halve the time of a given buffer, but it also doubles the work per second. On many systems you end up raising the buffer to stay stable, which cancels the gain. Changing the buffer size at 44.1 or 48 kHz is usually the more predictable way to tune low latency.

Sample rate with more than one device

ASIO4ALL can combine inputs and outputs from several Windows devices into one ASIO session. Every enabled device has to work at the session rate, so one device that does not support the chosen rate can stop the whole session from starting or make it behave unpredictably.

Even when two devices both run at 48 kHz, each has its own clock, and those clocks can run at slightly different physical speeds. That can cause slow drift, clicks or gaps over long takes. The device aggregation and clock sync guide covers this in detail, and the publisher's device aggregation page explains the shared-clock requirement.

Note: If only a second device introduces a problem, check its supported rates first and then how its clock relates to the first device. Disable it temporarily to confirm it is the cause.

Verify input, output and timing at the chosen rate

Play a short clip, then record a new one on the intended input. The test checks both directions at the chosen rate. Keep the rest of the setup stable during the comparison so you change one thing at a time.

Common symptoms and what they point to

  • Audio plays at the wrong pitch or speed: the file's rate and the session rate do not match. Check the project setting and how the DAW handles imported files.
  • The session will not start at one rate: the device may not support it. Try the other common rate and check the device documentation.
  • Distortion only at 44.1 kHz: test the Always Resample option as described above.
  • Clicks that grow over a long take with two devices: likely clock drift rather than a rate setting.

Keep timing in mind

If recorded takes land consistently early or late after you change rate, re-check the offset. The latency compensation guide explains how to measure it with a loopback test. A note of your working rate, buffer and devices makes it easy to return to a known-good setup.

Frequently asked questions

In most setups the rate is requested by the DAW, so set it in the host's project or audio settings. The ASIO4ALL control panel is where you choose devices and advanced options such as Always Resample.

Use 44.1 kHz for music projects and 48 kHz for video or podcast work unless the delivery spec says otherwise. Both work well when the device supports them.

No. The Windows default format controls the shared-mode mix used by ordinary apps. The ASIO host can request its own rate for the session, so check the rate the DAW reports.

A higher rate shortens the time of a given buffer, but it also increases processing load. Adjusting the buffer size at 44.1 or 48 kHz is usually the more reliable way to reach low latency.

Sources and further reading

ASIO4ALL Editorial Team